Can be used worldwide for any induction application
TRUMPF Hüttinger is bringing a new generation to market. The generators of the TruHeat MF Series G3 are particularly suitable for applications in crystal growing and epitaxy. Our decades of experience with the industry-leading predecessor models of the TruHeat MF Series 3000 are incorporated in this new generation in terms of reliability and robustness, along with optimized cost considerations.
Can be used worldwide without technical modifications
Constant availability and cost savings due to low downtimes
Cost savings thanks to an economic and robust cooling concept
High efficiency factor of up to 94.5% and low operating costs
Broad range of applications
The experience gained from the market-leading predecessor model TruHeat MF 3000 contributes to even higher reliability and robustness with optimized cost considerations. Particularly for SiC. But also for the overall wide-ranging induction market.
Epitaxy
Deposition of single-crystal layers on a substrate of the same material, e.g. in LED manufacturing.
Crystal growing
The generators of the TruHeat MF Series G3 are predominantly used for demanding inductive heating tasks such as crystal growing - particularly the cultivation of silicon carbide (SiC).
Can be used flexibly and worldwide
The space requirements are low, which means it can be easily integrated in any application environment – the construction with a separate parallel oscillating circuit enables flexible arrangement in the process. Thanks to the variable supply voltage, the generators can be used globally without technical modifications; the wide variety of available interfaces facilitates configuration and operation.
Ideal solution for temperature-controlled processes
Parallel oscillating circuit technology reduces setup times, improves productivity and extends the application spectrum. Thanks to the flexible power regulation from almost 0% to 100%, temperature-controlled processes can be optimally controlled using the TruHeat MF Series G3 generators. Reliability and long-term stability in operation guarantee a high level of productivity and reproducibility of the results. The taps of the MF output transformer enable easy adjustment to various induction processes.
TruHeat MF 7000-80/200 G3
Compare product
|
TruHeat MF 7000-60/30 G3
Compare product
|
TruHeat MF 7000-60/200 G3
Compare product
|
TruHeat MF 7000-80/30 G3
Compare product
|
TruHeat MF 7000-300 G3
Compare product
|
TruHeat MF Series G3
Compare product
|
TruHeatMF 3000-30 G3
Compare product
|
TruHeat MF 3000-50 G3
Compare product
|
TruHeat MF 3000-40 G3
Compare product
|
TruHeat MF 5000-40 G3
Compare product
|
TruHeat MF 5000-10 G3
Compare product
|
TruHeat MF 3000-10 G3
Compare product
|
TruHeat MF 5000-20 G3
Compare product
|
TruHeat MF 3000-20 G3
Compare product
|
TruHeat MF 5000-30 G3
Compare product
|
TruHeat MF 7000-100/30 G3
Compare product
|
TruHeat MF 7000-100/200 G3
Compare product
|
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Network connection data | |||||||||||||||||
Line voltage | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) |
Line frequency | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz |
Line input power | 97 kVA | 73 kVA | 73 kVA | 97 kVA | 361 kVA | 61 kVA | 37 kVA | 61 kVA | 49 kVA | 49 kVA | 13 kVA | 13 kVA | 25 kVA | 25 kVA | 37 kVA | 121 kVA | 121 kVA |
Power factor | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 |
Output | |||||||||||||||||
Rated power | 80 kW | 60 kW | 60 kW | 80 kW | 300 kW | 50 kW | 30 kW | 50 kW | 40 kW | 40 kW | 10 kW | 10 kW | 20 kW | 20 kW | 30 kW | 100 kW | 100 kW |
Maximum output current | 616 A eff | 616 A eff | 616 A eff | 616 A eff | 1326 A eff | 308 A eff | 308 A eff | 308 A eff | 308 A eff | 308 A eff | 154 A eff | 154 A eff | 154 A eff | 154 A eff | 308 A eff | 616 A eff | 616 A eff |
Maximum output voltage | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff |
Nominal operating frequency | 20 kHz - 200 kHz | 5 kHz - 30 kHz | 20 kHz - 200 kHz | 5 kHz - 30 kHz | 5 kHz - 30 kHz | 5 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 30 kHz | 20 kHz - 200 kHz |
Length, power cable | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m |
Housing | |||||||||||||||||
Width | 600 mm | 600 mm | 600 mm | 600 mm | 1800 mm | 443 mm | 443 mm | 443 mm | 552 mm | 552 mm | 443 mm | 552 mm | 443 mm | 552 mm | 600 mm | 600 mm | |
Height | 1600 mm | 1600 mm | 1600 mm | 1600 mm | 1600 mm | 399 mm | 399 mm | 399 mm | 511 mm | 511 mm | 399 mm | 511 mm | 399 mm | 511 mm | 1600 mm | 1600 mm | |
Depth | 800 mm | 800 mm | 800 mm | 800 mm | 800 mm | 759 mm | 759 mm | 759 mm | 820 mm | 820 mm | 759 mm | 820 mm | 759 mm | 820 mm | 800 mm | 800 mm | |
Weight | 349 kg | 349 kg | 349 kg | 349 kg | 968 kg | 98 kg | 98 kg | 98 kg | 140 kg | 140 kg | 98 kg | 140 kg | 98 kg | 140 kg | 349 kg | 349 kg | |
IP protection class | 54 | 54 | 54 | 54 | 54 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 54 | 54 | |
Communication interfaces | |||||||||||||||||
Analog/digital | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
RS 232/RS 485 | - | ✓ | - | ✓ | - | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | - | |
PROFIBUS | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Ethernet | - | ✓ | - | ✓ | - | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | - | |
EtherCAT | ✓ | ✓ | ✓ | ✓ | |||||||||||||
DeviceNet | ✓ | ✓ | ✓ | ✓ | |||||||||||||
Cooling requirements | |||||||||||||||||
Maximum water pressure | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | |
Minimum pressure difference | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | |
Minimum flow rate | 26 l/min | 13 l/min | 26 l/min | 13 l/min | 40 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 13 l/min | 26 l/min | |
Maximum coolant temperature | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | |
General | |||||||||||||||||
Overall efficiency | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 92 % | 92 % | 94 % | 94 % | 95 % | 95 % | 95 % | |
Certificates / standards | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | |
Ambient conditions | |||||||||||||||||
Outside temperature | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C |
TruHeat MF 7000-80/200 G3
|
TruHeat MF 7000-60/30 G3
|
TruHeat MF 7000-60/200 G3
|
TruHeat MF 7000-80/30 G3
|
TruHeat MF 7000-300 G3
|
TruHeat MF Series G3
|
TruHeatMF 3000-30 G3
|
TruHeat MF 3000-50 G3
|
TruHeat MF 3000-40 G3
|
TruHeat MF 5000-40 G3
|
TruHeat MF 5000-10 G3
|
TruHeat MF 3000-10 G3
|
TruHeat MF 5000-20 G3
|
TruHeat MF 3000-20 G3
|
TruHeat MF 5000-30 G3
|
TruHeat MF 7000-100/30 G3
|
TruHeat MF 7000-100/200 G3
|
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Network connection data | |||||||||||||||||
Line voltage | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) | (±10%) |
Line frequency | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz | 45 Hz - 65 Hz |
Line input power | 97 kVA | 73 kVA | 73 kVA | 97 kVA | 361 kVA | 61 kVA | 37 kVA | 61 kVA | 49 kVA | 49 kVA | 13 kVA | 13 kVA | 25 kVA | 25 kVA | 37 kVA | 121 kVA | 121 kVA |
Power factor | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 |
Output | |||||||||||||||||
Rated power | 80 kW | 60 kW | 60 kW | 80 kW | 300 kW | 50 kW | 30 kW | 50 kW | 40 kW | 40 kW | 10 kW | 10 kW | 20 kW | 20 kW | 30 kW | 100 kW | 100 kW |
Maximum output current | 616 A eff | 616 A eff | 616 A eff | 616 A eff | 1326 A eff | 308 A eff | 308 A eff | 308 A eff | 308 A eff | 308 A eff | 154 A eff | 154 A eff | 154 A eff | 154 A eff | 308 A eff | 616 A eff | 616 A eff |
Maximum output voltage | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff | 600 V eff |
Nominal operating frequency | 20 kHz - 200 kHz | 5 kHz - 30 kHz | 20 kHz - 200 kHz | 5 kHz - 30 kHz | 5 kHz - 30 kHz | 5 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 200 kHz | 5 kHz - 30 kHz | 20 kHz - 200 kHz |
Length, power cable | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m | 5 m - 25 m |
Housing | |||||||||||||||||
Width | 600 mm | 600 mm | 600 mm | 600 mm | 1800 mm | 443 mm | 443 mm | 443 mm | 552 mm | 552 mm | 443 mm | 552 mm | 443 mm | 552 mm | 600 mm | 600 mm | |
Height | 1600 mm | 1600 mm | 1600 mm | 1600 mm | 1600 mm | 399 mm | 399 mm | 399 mm | 511 mm | 511 mm | 399 mm | 511 mm | 399 mm | 511 mm | 1600 mm | 1600 mm | |
Depth | 800 mm | 800 mm | 800 mm | 800 mm | 800 mm | 759 mm | 759 mm | 759 mm | 820 mm | 820 mm | 759 mm | 820 mm | 759 mm | 820 mm | 800 mm | 800 mm | |
Weight | 349 kg | 349 kg | 349 kg | 349 kg | 968 kg | 98 kg | 98 kg | 98 kg | 140 kg | 140 kg | 98 kg | 140 kg | 98 kg | 140 kg | 349 kg | 349 kg | |
IP protection class | 54 | 54 | 54 | 54 | 54 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 54 | 54 | |
Communication interfaces | |||||||||||||||||
Analog/digital | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
RS 232/RS 485 | - | ✓ | - | ✓ | - | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | - | |
PROFIBUS | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |
Ethernet | - | ✓ | - | ✓ | - | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | - | |
EtherCAT | ✓ | ✓ | ✓ | ✓ | |||||||||||||
DeviceNet | ✓ | ✓ | ✓ | ✓ | |||||||||||||
Cooling requirements | |||||||||||||||||
Maximum water pressure | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | 6 bar | |
Minimum pressure difference | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | 3 bar | |
Minimum flow rate | 26 l/min | 13 l/min | 26 l/min | 13 l/min | 40 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 11 l/min | 13 l/min | 26 l/min | |
Maximum coolant temperature | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | 35 °C | |
General | |||||||||||||||||
Overall efficiency | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 92 % | 92 % | 94 % | 94 % | 95 % | 95 % | 95 % | |
Certificates / standards | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | CE, NRTL (optional), Semi F47-0706, FCC | |
Ambient conditions | |||||||||||||||||
Outside temperature | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C | 10 °C - 40 °C |
The technical data of all product versions as a download.
With an outer circle, the load (induction coil + workpiece) can be optimally adapted to the RF generator so that this can always output the maximum power. Various outer circles are available for a variety of applications.
For safe disconnection of the system from the electric power.
The output voltage can be switched from 300 V to 600 V and is therefore ideal for demanding heating processes.
Web-based GUI
With the web-based graphical user interface, the generator can be conveniently operated, configured and monitored from a PC or laptop, without any software.
This product range and information may vary depending on the country. Subject to changes to technology, equipment, price, and range of accessories. Please get in touch with your local contact person to find out whether the product is available in your country.